Advertisements


Thrombite™ Clot Retriever Device
Price: | US$ 45-1300 |
---|---|
Minimum Order: | 10 |
Payment Terms: | T/T |
Port of Export: |
Product Details
Model No.: | Brand Name: |
---|
Certification: | |
---|---|
Specification: | The Thrombite™ clot retrieval, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels. |
Packaging & Delivery
Packaging: | |
---|---|
Delivery/Lead Time: | 2-12 weeks |
Production Capacity: |
Product Description
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ clot retrieval, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
CLOT RETRIEVAL DEVICES FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
Radiopaque markers on the distal end of the device increase device visibility
3 markers for the sizes with 3.0 and 4.0mm diameter
4 markers for the sizes with 5.0 and 6.0mm diameter
Advanced stent surface treatment process
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
How a Stent Retriever Procedure Is Performed
Stent retrieval device procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.
Thrombite™ Product code Diameter D(mm) Recommended Vessel Diameter(mm) Recommende Microcatheter ID (inch) Working Length A(mm) Stent Length B(mm) System Length(mm)
Min. Max.
3MM CRD-3-15 3 1.5 3 0.21 15 27 1900
CRD-3-20 3 1.5 3 0.21 20 32 1900
CRD-3-25 3 1.5 3 0.21 25 37 1900
CRD-3-30 3 1.5 3 0.21 30 42 1900
4MM CRD-4-15 4 2 4 0.21 15 27 1900
CRD-4-20 4 2 4 0.21 20 32 1900
CRD-4-25 4 2 4 0.21 25 37 1900
CRD-4-30 4 2 4 0.21 30 42 1900
5MM CRD-5-15 5 2.5 5 0.027 15 27 1900
CRD-5-20 5 2.5 5 0.027 20 32 1900
CRD-5-25 5 2.5 5 0.027 25 37 1900
CRD-5-30 5 2.5 5 0.027 30 42 1900
6MM CRD-6-15 6 3 5.5 0.027 15 27 1900
CRD-6-20 6 3 5.5 0.027 20 32 1900
CRD-6-25 6 3 5.5 0.027 25 37 1900
CRD-6-30 6 3 5.5 0.027 30 42 1900
Now the price of endovascular clot retrieval devices is reasonable, if you have needs, please contact us.
We are one of leading neurovascular medical device companies in the peripheral and neurovascular interventional medical device market in China. As a fully integrated medical device company, Ton-bridge medical has strong R&D and manufacturing capabilities, multiple specialized technology platforms, and proven commercialization capabilities. Led by our talented management team, we strive to provide best medical services and cutting-edge technical solutions to physicians and patients in China and around the world.
SUPPLIER PROFILE
|
|||
---|---|---|---|
Company: | ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. | ||
City/State | Hangzhou, Zhejiang | Country: |
China ![]() |
Business Type: | Export - Manufacturer / Trading Company | Established: | 2012 |
Member Since: | 2022 | Contact Person | Zyloxtb com |
SUPPLIER PROFILE
City/State/Country -
Hangzhou, Zhejiang
China 

Business Type -
Export - Manufacturer / Trading Company
Established -
2012
Member Since -
2022
Contact Person -
Zyloxtb com